Issue 865: Adding heavy mods in Peptide Settings does not add "Ratio to Heavy" normalization to Quantification tab

issues
Status:closed
Assigned To: Guest
Type: Defect
Area: Skyline
Priority: 1
Milestone: 21.2
Opened:2022-01-22 11:51 by Brendan MacLean
Changed:2022-02-14 14:01 by Brendan MacLean
Resolved:2022-02-07 07:50 by Nick Shulman
Resolution:Fixed
Closed:2022-02-14 14:01 by Brendan MacLean
2022-01-22 11:51 Brendan MacLean
Title»Adding heavy mods in Peptide Settings does not add "Ratio to Heavy" normalization to Quantification tab
Assigned To»Brendan MacLean
Type»Defect
Area»Skyline
Priority»2
Milestone»21.2
This one is kind of a bummer for a tutorial I am working on.

Starting with default settings, if I add K and R label modifications in the Peptide Settings - Modifications tab, and then switch to the Quantification tab, I do not see "Ratio to Heavy" as a normalization option. I need to OK the form and reopen it to see this option.

It would be great if this could get fixed in 21.2 to make the flow of the tutorial not require closing the form and reopenning it.

2022-01-22 11:51 Brendan MacLean
Assigned ToBrendan MacLean»Nick Shulman
Priority2»1

2022-02-07 07:50 Nick Shulman
resolve as Fixed
Statusopen»resolved
Assigned ToNick Shulman»Brendan MacLean
This got fixed as part of PR #1985

2022-02-14 14:01 Brendan MacLean
close
Statusresolved»closed
Assigned ToBrendan MacLean»Guest