Issue 483: Precursor isotope peaks (M+1, M+2) not automatically shown for small molecules

issues
Status:closed
Assigned To:Guest
Type:Defect
Area:Skyline
Priority:3
Milestone:3.6
Opened:2016-10-20 02:49 by Cedric
Changed:2017-10-18 08:36 by Brendan MacLean
Resolved:2016-10-26 08:33 by Brian Pratt
Resolution:Fixed
Closed:2017-10-18 08:36 by Brendan MacLean
2016-10-20 02:49 Cedric
Title»Precursor isotope peaks (M+1, M+2) not automatically shown for small molecules
Assigned To»Michael
Type»Defect
Area»Skyline
Priority»3
Milestone»3.6
Within small molecules full scan/DIA experiment (QTOF Data), precursor isotope peaks (M+1, M+2) are not automatically shown with the molecule (although specified in MS1 filtering setting with 3 Peaks Count). Only the precursor mass is shown

2016-10-26 08:33 Brian Pratt
resolve as Fixed
Statusopen»resolved
Assigned ToMichael»Brian Pratt
It was just a settings issue - precursor ions weren't turned on.

2017-10-18 08:36 Brendan MacLean
close
Statusresolved»closed