Issue 461: Unable to change transition settings

issues
Status:closed
Assigned To:Guest
Type:Defect
Area:Skyline
Priority:3
Milestone:3.6
Opened:2016-04-06 15:38 by jdawlaty
Changed:2017-06-10 06:19 by Brendan MacLean
Resolved:2016-04-06 16:47 by Nick Shulman
Resolution:Fixed
Closed:2017-06-10 06:19 by Brendan MacLean
2016-04-06 15:38 jdawlaty
Title»Unable to change transition settings
Assigned To»Brendan MacLean
Type»Defect
Area»Skyline
Priority»3
Milestone»3.6
I have a file that seems to have been corrupted. I am unable to change some of the Transition Settings.
"Transition Settings" -> Filter tab -> Ion types:
When I change "y, b, p" to "y, b" by deleting p (and the comma), Click OK and I get an error message. This also occurs when I try to change Precursor charges, Ion charges, or make changes to Special ions.

I do not have problems like this with other files.
 
 20160405 mTBI winged peptides PRM.sky
 Error message.txt

2016-04-06 16:04 Brendan MacLean
Assigned ToBrendan MacLean»Nick Shulman
Mind having a look?

2016-04-06 16:47 Nick Shulman
resolve as Fixed
Statusopen»resolved
This error can sometimes happen if you have checked "Dynamic min product m/z" on:
Settings > Transition Settings > Filter

the workaround in Skyline 3.5 is to uncheck that box.

This bug has been fixed in Skyline-Daily.

2017-06-10 06:19 Brendan MacLean
close
Statusresolved»closed
Assigned ToNick Shulman»Guest