Issue 341: Centroided spectra show up with profile lines in full-scan graph

Status:closed
Assigned To:Guest
Type:Defect
Area:Skyline
Priority:3
Milestone:2.6
Opened:2014-08-15 12:03 by Brendan MacLean
Changed:2015-07-06 09:38 by Brendan MacLean
Resolved:2014-08-28 15:45 by donmarsh
Resolution:Fixed
Closed:2015-07-06 09:38 by Brendan MacLean
2014-08-15 12:03 Brendan MacLean
Title»Centroided spectra show up with profile lines in full-scan graph
Assigned To»donmarsh@proteinms.net
Type»Defect
Area»Skyline
Priority»3
Milestone»2.6
Even when underlying full-scan data is centroided, the full-scan graph still shows lines (and shading) connecting the points, which looks pretty odd. Nick says it is possible to find out from ProteoWizard whether spectra are centroided. The full-scan graph should make this check, and not show connecting lines when spectra are centroided.

2014-08-28 15:45 donmarsh
resolve as Fixed
Statusopen»resolved
Assigned Todonmarsh@proteinms.net»Brendan MacLean
I tested on centroided and non-centroided data. Please review the one-line fix I described in email. If my assumptions are wrong, I might need a slightly more complicated implementation.

2015-07-06 09:38 Brendan MacLean
close
Statusresolved»closed
Assigned ToBrendan MacLean»Guest