Issue 906: A few details working with Bruker PASER assay library lists

Status:closed
Assigned To:Guest
Type:Defect
Area:Skyline
Priority:3
Milestone:22.2
Opened:2022-09-21 14:14 by Brian Pratt
Changed:2023-08-17 14:17 by Brian Pratt
Resolved:2023-08-17 14:17 by Brian Pratt
Resolution:Fixed
Closed:2023-08-17 14:17 by Brian Pratt
2022-09-21 14:14 Brian Pratt
Title»A few details working with Bruker PASER assay library lists
Assigned To»Brian Pratt
Type»Defect
Area»Skyline
Priority»3
Milestone»22.2
1) It would be ideal to recognize their "PrecursorIonMobility" header as a synonym for 1/K0 ion mobility

2) It's confusing in the context of Assay Library import that we have column header selections like "Explicit 1/K0" when the data is headed for a library - need a parallel set of header names without "Explicit" in them.
 
 _ip2_ip2_data_paser_spectral_library__timsTOFHT_plasma_lib_dilution.tsv

2023-08-17 14:17 Brian Pratt
resolve as Fixed
Statusopen»resolved
Fixed in Commit 3cb6d0e94dea85b22641b9faa6024d4c2c3c35eb:

Author: Brian Pratt <bspratt@proteinms.net>
Date: Friday, September 30, 2022 6:41 PM
Parent: c6433fcd

For Bruker PaSER support: (#2297)

Bruker PaSER support improvements:
Recognize "PrecursorIonMobility" as a synonym for "1/K0"
Tidy up the Assay Library import UI so that column ID dropdowns don't use "Explicit" terminology, since these are library values, not per-node values (e.g. "Collision Energy" instead of "Explicit Collision Energy")

2023-08-17 14:17 Brian Pratt
close
Statusresolved»closed
Assigned ToBrian Pratt»Guest